Energy ADE V0.1
Contents |
[edit] CityGML ADE Energy Version 0.1
[edit] General Description and Commenting rule
Download CityGML ADE Energy V0.1
The following tables list the elements of the CityGML ADE Energy V 0.1. Please use this section to get an overview and comment on the concept.
If you comment please do it as follows:
TOPIC - General Claudia 2013-11-11:I suggest that we try to get a version which we all agree upon, wish us all good luck for that NoName 2013-11-11: Yes I think that's a good idea Coors 2013-11-13: why do we need a mean uValue as building attribute? a uValue per BoundarySurface would make sence. Coors 2013-11-13: In a future version, we need Boundary Surfaces for LoD1 as well.
TOPIC - CodeLists Claudia 2013-11-11: I don't see a solution yet for the handling of the different Codelists (Building Function, RoofType etc) NoName 2013-11-11: Yes thats an issue, I suggest we define our own codelists and probably have to semi-automatic (via GUI) have to align the input data set with the requirements of the Codelist defined in SIMSTADT
[edit] Mandatory or important CityGML - Building Elements and Attributes for SIMSTADT
Parent Element | CityGML Element | Substitution | Type | Defined by | Source | Mandatory
Difficult to define as it depends on the usage of the ADE... |
Comment |
---|---|---|---|---|---|---|---|
cityObjectMember | bldg:Building gml:id | Attribute of <Building Element> | CityGML Building ID derived from ALKIS | yes | Within the DataDictionary[1], the ID is defined as buildingUnitID. We should decide, if this must be always the gml:id or if this could be another ID and should then be integrated within the CityGML ADE Energy as UnitID
| ||
bldg:BuildingPart gml:id | Attribute of <BuildingPart Element> | CityGML BuildingPart ID derived from ALKIS | yes | Within the DataDictionary[2], the ID is defined as buildingUnitID. We should decide, if this must be always the gml:id or if this could be another ID and should then be integrated within the CityGML ADE Energy as UnitID | |||
bldg:Building | bldg:function | gml:CodeType | DataDictionary[3] | yes | There are various codelists available we should be able to interpretate at least the basic CityGML Codelist, the Codelist of the AdV Codelist for building function and the Ludwigsburg Code List.
See the following general statement: The codelists for the values of enumerative attributes like "class", "function", "usage" etc. do not belong to the normative part of the CityGML specification, because these typically will require different values for different countries. The codelists provided in the specification document are to be considered as an example for the definition of appropriate codelists. Since they have been defined by the SIG 3D they can be found in (and used from) the following repository | ||
bldg:roofType | gml:CodeType | DataDictionary[4] | no | See Codelists_AdV | |||
bldg:storeysAboveGround | xsd:nonNegativeInteger | DataDictionary[5] | no | ||||
bldg:storeysBelowGround | xsd:nonNegativeInteger | DataDictionary[6] | no |
| |||
bldg:storeysHeightsAboveGround | gml:MeasureOrNullListTyp | DataDictionary[7] | no | ||||
bldg:storeysHeightsBelowGround | gml:MeasureOrNullListTyp | DataDictionary[8] | no | ||||
bldg:yearOfConstruction | xsd:gYear | DataDictionary[9] | yes |
[edit] CITYGML ADE ENERGY VERSION 0.1
[edit] CityGML ADE Energy - buildingPhysics
Parent Element | ADE Element | Substitution | Type | Defined by | Source | Mandatory
Difficult to define as it depends on the usage of the ADE... |
Comment |
---|---|---|---|---|---|---|---|
bldg:Building | energy:buildingPhysics | bldg:_GenericApplicationPropertyOfAbstractBuilding | buildingPhysicsType | DataDictionary[10] | various | yes | The element buildingPhysics groups all building related elements defined in the DataDictionary within the EnergyADE module BuildingPhysics |
energy:buildingPhysics | energy:yearOfRefurbishment | none | xsd:gYear | DataDictionary[11] | Difficult to get on city level, experience is that this information has to be collected or estimated via survey or on-site visit | optional (difficult to get) | |
energy:ageClass | none | gml:CodeType | DataDictionary[12] | Can be retrieved based on bldg:yearOfconstruction | redundancy to yearOfConstruction... | CodeLists.zip | |
energy:buildingType | none | gml:CodeType | DataDictionary[13] | Should be available from the city municipality or can be estimated by statistical methods based on geometry | yes (if not available it must be calculated based on geometry) | CodeLists.zip | |
energy:atticStoreyType | none | energy:extraRoomHeatingType | DataDictionary[14] | Should be available from the city municipality or can be estimated by statistical methods based on geometry | yes (if not available it must be calculated based on geometry) | ||
energy:cellarType | none | energy:extraRoomHeatingType | DataDictionary[15] | Should be available from the city municipality or can be estimated by statistical methods based on geometry | yes (if not available it must be calculated based on geometry) | ||
energy:heatedArea | none | gml:MeasureOrNullListType | DataDictionary[16] | ??? | |||
energy:meanUvalue | none | gml:MeasureOrNullListType | DataDictionary[17] | ??? |
[edit] CityGML ADE Energy - buildingDimensions
Parent Element | ADE Element | Substitution | Type | Defined by | Source | Mandatory
Difficult to define as it depends on the usage of the ADE... |
Comment |
---|---|---|---|---|---|---|---|
bldg:Building | energy:buildingDimensions | bldg:_GenericApplicationPropertyOfAbstractBuilding | buildingDimensionsType | DataDictionary[18] | yes for internal processes as the values grouped by buildingDimensions are required for the energy demand simulation | The element buildingDimensions groups all building related (with SIMSTADT geometric preprocessing) calculated dimensions defined in the DataDictionary within the EnergyADE module BuildingPhysics | |
energy:buildingDimensions | energy:volume | none | gml:MeasureOrNullListType | DataDictionary[19] | SIMSTADT geometric preprocessing | ||
energy:roofArea | none | gml:MeasureOrNullListType | DataDictionary[20] | SIMSTADT geometric preprocessing | |||
energy:groundArea | none | gml:MeasureOrNullListType | DataDictionary[21] | SIMSTADT geometric preprocessing | |||
energy:meanHeight | none | gml:MeasureOrNullListType | DataDictionary[22] | SIMSTADT geometric preprocessing | |||
energy:ridgeHeight | none | gml:MeasureOrNullListType | DataDictionary[23] | SIMSTADT geometric preprocessing | |||
energy:eavesHeight | none | gml:MeasureOrNullListType | DataDictionary[24] | SIMSTADT geometric preprocessing |
|
[edit] CityGML ADE Energy - surfacePhysics
Parent Element | ADE Element | Substitution | Type | Defined by | Source | Mandatory
Difficult to define as it depends on the usage of the ADE... |
Comment |
---|---|---|---|---|---|---|---|
bldg:BoundarySurface | energy:surfacePhysics | bldg:_GenericApplicationPropertyOfBoundarySurface | surfacePhysicsType | DataDictionary[25] | yes for internal processes as the values grouped by surfacePhysics are required for the energy demand simulation | The element buildingDimensions groups all building related (with SIMSTADT geometric preprocessing) calculated dimensions defined in the DataDictionary within the EnergyADE module BuildingPhysics | |
energy:surfacePhysics | energy:visibleSurfaceArea | none | gml:MeasureType | DataDictionary[26] | SIMSTADT geometric preprocessing | ||
energy:blindSurfaceArea | none | gml:MeasureType | DataDictionary[27] | SIMSTADT geometric preprocessing | |||
energy:azimuth | none | gml:MeasureType | DataDictionary[28] | SIMSTADT geometric preprocessing | |||
energy:inclination | none | gml:MeasureType | DataDictionary[29] | SIMSTADT geometric preprocessing | |||
energy:uValue | none | gml:MeasureType | DataDictionary[30] | SIMSTADT preprocessing | |||
energy:windowType | none | gml:CodeType | Defined by: CodeList --> windowTypeType based on Energiebilanz-Toolbox_IWU | ??? | |||
energy:windowRatio | none | gml:integerOrNull, default value = 20 | DataDictionary[31] | ??? On longterm automatic image processing of facade and aerial images could be possible but with high error level. Otherwise the Ratio only can be estimated on city level |
| ||
energy:constructionType | none | constructionTypeType TODO | Defined by: TODO | ??? On City Level ??? |
[edit] CityGML ADE Energy - energyDemand
Parent Element | ADE Element | Substitution | Type | Defined by | Source | Mandatory
Difficult to define as it depends on the usage of the ADE... |
Comment |
---|---|---|---|---|---|---|---|
bldg:Building | energy:energyDemand | bldg:_GenericApplicationPropertyOfAbstractBuilding | energyDemandType | DataDictionary[32] | no | ||
energy:energyDemand | energy:spaceHeatingDemand | none | gml:MeasureType | DataDictionary[33] | SIMSTADT INSEL SIMULATION OUTPUT | ||
energy:primaryEnergyDemand | none | gml:MeasureType | DataDictionary[34] | SIMSTADT INSEL SIMULATION OUTPUT |
| ||
energy:emissionCO2 | none | gml:MeasureType | DataDictionary[35] | SIMSTADT INSEL SIMULATION OUTPUT |